GAF300-10-11-70 ABB DC Contactors

GAF300-10-11-70


GAF300-10-11-70.png


General Information

Extended Product Type:
GAF300-10-11-70
Product ID:
1SFL557025R7011
EAN:
7320500400784
Catalog Description:
GAF300-10-11 100-250V 50/60Hz / 100-250V DC Contactor
Long Description:
A 3-pole Contactor suitable  for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 100-250 V, AC/DC



Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Dimension Diagram:

Dimensions

Product Net Width:
140 mm
Product Net Depth / Length:
180.5 mm
Product Net Height:
227 mm
Product Net Weight:
5.5 kg

Technical

Number of Main Contacts NO:
1
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Rated Operational Voltage:
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Operational Current DC-1 (Ie):
(1000 V) 3 Poles in Series, 40 °C 500 A
(1000 V) 3 Poles in Series, 55 °C 400 A
(1000 V) 3 Poles in Series, 70 °C 325 A
(220 V) 3 Poles in Series, 40 °C 500 A
(220 V) 3 Poles in Series, 55 °C 400 A
(220 V) 3 Poles in Series, 70 °C 325 A
(400 V) 3 Poles in Series, 40 °C 500 A
(400 V) 3 Poles in Series, 55 °C 400 A
(400 V) 3 Poles in Series, 70 °C 325 A
(600 V) 3 Poles in Series, 40 °C 500 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
300 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1)  0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage DC 2 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 520 V·A
Connecting Capacity Main Circuit:
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
<div class="row g-0 py-1 py-lg-2 border-bottom" style="box-sizing: border-box; --pis-gutter-x: 0; --pis-gutter-y: 0; display: flex; flex-wrap: wrap; margin-top: calc(-1*var(--pis-gutter-y)); margin-right: calc(-0.5*var(--pis-gutter-x)); margin-left: calc(-0.5*var(--pis-gutter-
PREVIOUS:This is already the first article NEXT:GF1325-20-22-51 ABB DC Contactors

NEWS

CONTACT US

Starlight Electric Limited

TEL:+86-15999815042

EMAILL:sales@starlighteltd.com // sales2@starlighteltd.com

ADDRESS:

Copyright © 2012-2028 Starlight Electric Limited Powered by  .

Add:  Tel: +86-15999815042  E-mail: sales@starlighteltd.com // sales2@starlighteltd.com